上海含灵机械设备有限公司现货销售STEGO温湿度一体控制器ETF012 230VAC 01230.0-00
电话:021-60548556021-60548557手机13817136125
传真:021-56183857
邮箱:infohanling@aliyun.com
QQ:283190163909955817
www.shhylink.com
TECHNICAL DATA
Switch difference (temperature)Switch difference (humidity)Reactiotime (humidity)CotactypeService lifeMax. switching capacity (relay output)Max. inrush cueOptical indicatorConectionMouingCasingDimensionsWeightFiing positionOperating/StorageemperatureOperating/Storage humidityProtectiotypeApprovals
2K (±1Kolerance) a+25°C (+77°F), 50% RH |
4% RH (±1%olerance) a+25°C (+77°F), 50% RH |
approx. 5 sec. |
change-over cotac(relay) |
VDE: NO/NC > 15,000 cycles UL: NO/NC > 30,000 cycles |
240VAC, 10 (1.6) A 60VDC, 0.6A¹ |
AC 30A for 10 sec. |
LED |
5-poleerminal, clampingorque 0.5Nm max.: igid/stranded² wire 2.5mm² (AWG 14) |
clip for 35mm DINail, EN 60715 |
plastic accordingo UL94 V-0, lighgrey |
77 x 60 x 43mm |
approx. 0.2kg |
vertical |
-40o +60°C (-40o +140°F) |
max. 90% RH (non-condensing) |
IP20 |
VDE, UL File No. E164102, EAC |
¹oUL /cofirm/ied
² Wheconecting with stranded wires, wire end feules musbe used.
Art. No.Operating voltageSeingangeemperatureSeingange humidity
01230.0-00 | 100-240VAC, 50/60Hz (min. 90VAC, max. 265VAC) | 0o +60°C | 50o 90% RH |
01230.9-00 | 100-240VAC, 50/60Hz (min. 90VAC, max. 265VAC) | +32o +140°F | 50o 90% RH |
01230.1-00KTO 011 / KTS 011 | NC (Heating) or NO (Cooling) - StandardSTO 011 / STS 011 | NC (Heating) or NO (Cooling) - Small HysteresisFTO 011 / FTS 011 | NC (Heating) or NO (Cooling) - Tamper-proofZR 011 | Combination: NC/NOFTD 011 | Combination: NC/NO - Tamper-proofFZK 011 | Change-over Cotac(Heating/Cooling)ETR 011 | Electroic ThermostatETL 011 | Electroic Thermosta(DC, low signals)ET 011 | Electroic Thermosta(24VDC)MFR 012 | Mechanical HygrostatEFR 012 | Electroic HygrostatEFL 012 | Electroic Hygrosta(DC, low signals)ETF 012 | HygrothermETF 012 | Hygrotherm with exteal sensorSM 010 | Switch Module (24VDC and 48VDC)DCM 010 | Switch Module (DC 20Vo 56V)DCT 010 | Electroic Thermosta(DC 20Vo 56V)DCF 010 | Electroic Hygrosta(DC 20Vo 56V)Hazardous Area Thermosta | 24-48VDC (min. 20VDC, max. 60VDC) | 0o +60°C | 50o 90% RH |